Part 10: Model Construction Specification 10 - 26 8.6 Assembly Assembly of components shall be carried out so as to fulfil the specified tolerances. Precautions shall be taken so as to prevent galvanic corrosion produced by contact between different metallic materials. Requirements of § 6.9 and § 6.10 of EN 1090-2 shall be applied as appropriate.